Hi Sarah,
Please see below/ attached for a response in red, this also incorporates comments made to Natalee following the visit from David & Melanie on 27th May.
Any further queries, please let us know.
Regards,
Nik Clarke BSc (Hons) ACIAT
Director

Darley Abbey Mills
·
3rd Floor, The Long Mill ·
Derby · DE22 1DZ ·
M.
07539 362 395
·
T. 01332 363 355
· W.
www.morrisondesign.co.uk
Please note - Office based working is limited due to the current situation, a number of our team members are working remotely, therefore please make contact via email or mobile phone
if possible

@MDLarchitects
·
@MDLarchitects
·
@MDLarchitects
·
Morrison
Design Ltd
·
Morrison
Design Limited
Please
consider your environmental responsibility before printing this email.
From: Pearce, Sarah <Sarah.Pearce@ambervalley.gov.uk>
Sent: 11 May 2021 10:04
To: Nik Clarke <nclarke@morrisondesign.co.uk>
Cc: Winson, Claire <Claire.Winson@ambervalley.gov.uk>
Subject: [OFFICIAL] FW: [OFFICIAL] RE: AVA/2021/0226 - 80 King Street, Belper
Dear Nik,
I refer to your email below and our telephone conversation last week. I am sorry I have not been able to update as quickly as I indicated last week. We currently have a high volume of cases and are short staffed.
The Environmental Health (Pollution) section have responded as follows:
Although the premises are in the town centre, the proposed use is a significant departure from the existing approved use and could have significant adverse impacts on the residential amenity of sensitive receptors in the vicinity.
The location plan and proposed layout/elevations (both attached) suggest that the applicant also owns the adjoining commercial property at 82 King Street and both properties appear to be undergoing redevelopment, with some shared access
and facilities. I understand that no.82 has been empty for many years and that no.80 has been in retail use for many years; the external condition of both properties suggests that substantial works are required. Having visited to assess the site last week,
I have a number of concerns about the suitability of the premises for the proposed use and the lack information to determine the potential impact on residential amenity or to recommend appropriate conditions. The applicant will need to clarify the following
matters before I can comment further and before the application can be determined:
Section 19 of the application form states that opening hours are relevant to the proposal, but then states that they are ‘unknown’. Operating hours will need to be conditioned to protect the residential amenity
of sensitive receptors in the vicinity, so must be stated. It should be noted that the operating hours permitted could affect the viability of the business;
Happy with the conditions set out by Melanie Goodier on operating hours
The application form and the ‘Design & Access Statement’ refer to the proposed use as a ‘drinking establishment with expanded food provision’, and the layout/elevations
indicate that the cellar at the rear of no.80 would form a commercial kitchen. If the rear cellar is similar to others nearby, it is likely to have low/vaulted ceilings and flooding issues that may be problematic in a commercial kitchen.
The nature of the ‘expanded food provision’ is not stated and no indication is given of how the underground kitchen would be ventilated or cooking odours extracted.
Non-domestic kitchen extraction/ventilation systems should be risk-assessed and designed in accordance with EMAQ’s best practice document: ‘Control
of odour and noise from commercial kitchen exhaust systems’ (05 September 2018). A significance score and odour control requirement can be assigned according to criteria including: the degree of dispersion of extracted cooking odours, the proximity
of receptors, the size of the kitchen (number of covers) and the cooking type (odour and grease loading - a copy of the menu can be helpful).
Noise from the kitchen ventilation/extraction system will also need to be considered prior to determination.
Given that the building is in a Conservation Area, the proposed commercial ventilation/extraction system must meet our requirements for preventing nuisance from cooking
odours, as well as the visual amenity requirements of a Conservation Area;
The client has decided against installing a full gas kitchen, having liaised with a few ventilation companies, its clear due to the height of the ceiling & complexities of installing a flue within an existing
chimney this option isn’t viable, on that basis the occupier will use self-contained ovens/ appliances (all electrical) On this basis, a standard domestic extract is to be installed with a simple grille into the courtyard. The menu will reflect this.
No mention is made of any proposals for providing entertainment in the bars/function rooms. The ‘Design & Access Statement’ states that all timber windows will be replaced with double-glazing. Thermal double-glazed
timber windows, and the 9” solid brick walls also mentioned, are unlikely to prevent the breakout of amplified sound internally or externally, so further consideration must be given to structural and/or operational mitigation. The ground and first floor offices
at no.82 should provide some buffer between no.80 and the attached second floor flat at 84B, but it may not be sufficient to prevent flanking transmission and disturbance from amplified music and voices (the ground floor hair salon; first floor beauty salon,
which could return to residential use (as no.84A); and second floor flat at no.84 are in single ownership); the building attached to the other side is retail at ground floor and a hair salon at first floor, which wouldn’t be considered sensitive; the buildings
opposite also appear to be entirely commercial;
The upper room is no longer to be used as a “function room” & to be for “private dining” no music will be played in the upper “private dining” without prior notification/ approval. Added insulation to the wall
at first floor between 82 and 84, acoustic buffer layer to absorb noise to the front of both buildings at 80 & 82.
Happy with the conditions set out by Melanie Goodier on noise.
The ‘Ground Floor as Proposed’ refers to the provision of an external waste storage area in the rear yard behind no.80/82. Waste, particularly food waste, would need to be stored in rodent-proofed containers;
however, the only external access is via the covered passage, which is too narrow to allow access for a trade waste bin. A significant rodent issue has been identified in the immediate area and the rear yard and passageway also require effective pigeon-proofing
to address the current roosting problem. All waste will therefore need to be kept indoors until it is collected for disposal;
Waste – See below for an example of the container planned for storage in the courtyard, this will be bagged & emptied on specified trade waste days, Melanie Goodier was in agreement with this option during the
visit.
Pest – The client has engaged with Pestforce for their services to dispatch the pigeons & roosting issue, along with sanitisation, all under general licence 41. Works to commence this weekend. Happy with the conditions
set out by Melanie Goodier on this matter.

There are issues with the covered access passage to the rear of the premises. Putting aside any civil access matters, which are outside the scope of planning, the access is the only route to/from the second
floor flat (no.84B) and is the fire escape for the ground/first floor beauty/hair salon. Due to vandalism and unauthorised use, the door onto King Street is locked outside salon business hours: if the applicant intends to use this route as an emergency/fire
exit, this will need to be considered and it would be advisable to seek the views of the Fire Authority and Crime Prevention Officer at the planning stage, as these issues are relevant to the suitability of the building to the proposed use. Even if suitable,
to prevent disturbance and anti-social behaviour, the access and rear yard must not be used by customers at any time.
There will be no change operationally to King St. side, door ironmongery is to be replaced to allow the door to be opened from the alleyway as an escape & retain the existing
situation for flat 84B. The escape route has been approved by the fire brigade, see attached.
Customers will not use the rear yard at any time.
The points raised by the Environmental Health (Pollution) section will need to be addressed prior to a decision being made. I’d therefore be grateful if you could confirm whether you wish to submit additional information? In addition, should
you wish to address the above points, I’d be grateful if you could also agree an extension of time to allow the information to be submitted and for further consultation with the Environmental Health (Pollution) section to be undertaken. I’d suggest the 30
June as a revised date. Is this acceptable to you? Accepted previously
Please note that I am still waiting for comments from the Conservation Officer and will update you further once these have been received. –
We still haven’t received this, assumed none?
Kind regards,
Sarah
From: Winson, Claire <Claire.Winson@ambervalley.gov.uk>
Sent: 11 May 2021 09:36
To: Pearce, Sarah <Sarah.Pearce@ambervalley.gov.uk>
Subject: FW: [OFFICIAL] RE: AVA/2021/0226 - 80 King Street, Belper
From: Nik Clarke <nclarke@morrisondesign.co.uk>
Sent: 11 May 2021 09:33
To: Winson, Claire <Claire.Winson@ambervalley.gov.uk>
Cc: Gareth Murfin <Gareth@whitemoordavis.co.uk>; Jordan Johal <jjohal@morrisondesign.co.uk>
Subject: RE: [OFFICIAL] RE: AVA/2021/0226 - 80 King Street, Belper
Hi Claire,
Could you please confirm the situation for the above application?
I did speak to Sarah last week & said she would provide an update.
Many thanks
Regards,
Nik Clarke BSc (Hons) ACIAT
Director

St Alkmunds House
·
103 Belper Road ·
Derby DE1 3ES
M.
07530 536 637
·
T. 01332 363 355
· W.
www.morrisondesign.co.uk

@MDLarchitects
·
@MDLarchitects
·
@MDLarchitects
·
Morrison
Design Ltd ·
Morrison
Design Limited
Please
consider your environmental responsibility before printing this email.
From: Winson, Claire <Claire.Winson@ambervalley.gov.uk>
Sent: 29 April 2021 09:29
To: Nik Clarke <nclarke@morrisondesign.co.uk>
Subject: [OFFICIAL] RE: AVA/2021/0226 - 80 King Street, Belper
Dear Nik
Thank you for your email, I have forwarded it to the allocated planning officer to respond with an update.
Many thanks
Kind regards
Claire
From: Nik Clarke <nclarke@morrisondesign.co.uk>
Sent: 29 April 2021 09:16
To: Winson, Claire <Claire.Winson@ambervalley.gov.uk>
Cc: Gareth Murfin <Gareth@whitemoordavis.co.uk>
Subject: AVA/2021/0226 - 80 King Street, Belper
Hi Claire,
A decision on the above was due yesterday, could you please provide an update on the application?
Regards,
Nik Clarke BSc (Hons) ACIAT
Director

St Alkmunds House
·
103 Belper Road ·
Derby DE1 3ES
M.
07530 536 637
·
T. 01332 363 355
· W.
www.morrisondesign.co.uk

@MDLarchitects
·
@MDLarchitects
·
@MDLarchitects
·
Morrison
Design Ltd ·
Morrison
Design Limited
Please
consider your environmental responsibility before printing this email.
From: Winson, Claire <Claire.Winson@ambervalley.gov.uk>
Sent: 04 March 2021 10:47
To: Nik Clarke <nclarke@morrisondesign.co.uk>
Subject: [OFFICIAL] AVA/2021/0226 - 80 King Street, Belper
Dear Mr Clarke
Thank you for the planning application received for the above site.
The allocated planning officer has requested the description of the proposal to be condensed to ‘Change of use from book shop (use class E(a)) to bar (sui generis) including replacement shop front’
Please could you confirm if you agree to the description of the proposal being amended as above.
Many thanks
Kind regards
Claire
Claire Winson | Administrator
Amber Valley
Borough Council
Development Management | Town Hall, Ripley, Derbyshire, DE5 3BT
Email: claire.winson@ambervalley.gov.uk |
Telephone: 01773 841571 Ext: 2428
www.ambervalley.gov.uk
Making a difference for Amber Valley
This email is private. If you are not the intended recipient, please notify the sender by return, destroying the email without disclosing or relying upon it. We may by law have to disclose this email.
We monitor both sent and received emails. The attachments are opened at your own risk.
This email is private. If you are not the intended recipient, please notify the sender by return, destroying the email without disclosing or relying upon it. We may by law have to disclose this email.
We monitor both sent and received emails. The attachments are opened at your own risk.
This email is private. If you are not the intended recipient, please notify the sender by return, destroying the email without disclosing or relying upon it. We may by law have to disclose this email.
We monitor both sent and received emails. The attachments are opened at your own risk.