Dear Heather,
Please find attached P01-revA for approval. 
Thank you for orchestrating this so quickly, and thanks to Mel for her speedy responses.
 
Kind Regards
David
On 19/01/2023 08:55 GMT Wynne, Heather <heather.wynne@ambervalley.gov.uk> wrote:
 
 

Dear David,

 

Mel has come back in response to the amended plans. Please see the comments below.

 

Many thanks

Kind regards

Heather Wynne | Planning Assistant

Amber Valley Borough Council
Development Management | Town Hall, Ripley, Derbyshire, DE5 3BT
Email: 
heather.wynne@ambervalley.gov.uk | Telephone: 01773 841593
www.ambervalley.gov.uk

Making a difference for Amber Valley

 

From: Morris, Mel
Sent: 18 January 2023 17:45
To: Wynne, Heather <Heather.Wynne@ambervalley.gov.uk>
Subject: RE: [OFFICIAL] FW: AVA/2022/1021 and 0919 44 Long Row, Belper

 

Dear Heather

These details are much more refined and I think, on balance, they are acceptable and we can accept the use of EPDM if detailed as proposed.   I agree that this is a much better solution.  The reduction in the depth of the fascia and overhang and the use of a recessed rainwater pipe has made a significant difference.  I would like clarification over the finish of the eaves.  If this is intended to be painted timber that would be acceptable.  The detail of the lead flashing will require the bottom edge to be clipped and will probably be divided into a series of sheets which are connected with ‘welts’.  That would be quite subtle and provide a more interesting detail.  This is not shown on the drawing, so I suggest that we do have a couple of conditions stating:

 

Full details of the lead flashing to the eaves shall be submitted to and approved in writing by the Local Planning Authority. This shall be detailed to Lead Sheet Association guidelines and shall show cut lengths and method of fixing, jointing, and clipping.

Notwithstanding the submitted details, the proposed rainwater pipe shall be cast metal and painted.

 

Kind regards

Mel

 

 

 

Mel Morris | Heritage Consultant

Development Management

Amber Valley Borough Council

Town Hall, Ripley, Derbyshire, DE5 3BT

Email: Mel.Morris@ambervalley.gov.uk

Tel: 07825 935295

 

From: Wynne, Heather <Heather.Wynne@ambervalley.gov.uk>
Sent: 18 January 2023 15:56
To: Morris, Mel <Mel.Morris@ambervalley.gov.uk>
Subject: FW: [OFFICIAL] FW: AVA/2022/1021 and 0919 44 Long Row, Belper

 

Hi Mel,

 

The agent has come back with the below and the attached drawings. Please let me know if you require anything else.

 

Thanks

Heather

Heather Wynne | Planning Assistant

Amber Valley Borough Council
Development Management | Town Hall, Ripley, Derbyshire, DE5 3BT
Email: 
heather.wynne@ambervalley.gov.uk | Telephone: 01773 841593
www.ambervalley.gov.uk

Making a difference for Amber Valley

 

From: David Guy <info@dg4design.co.uk>
Sent: 18 January 2023 15:29
To: Wynne, Heather <Heather.Wynne@ambervalley.gov.uk>; fsnorthall@gmail.com
Subject: Re: [OFFICIAL] FW: AVA/2022/1021 and 0919 44 Long Row, Belper

 

Dear Heather,

Please find attached updated planning drawing E01 revB - this shows a reduced eaves detail, capped with a lead flashing. The new section detail (buidling regulations) ref:P01 more fully explores the construction, and the view.jpgs help illustrate the extent of lead made visible.

 

The roof should be lightweight in construction - as only timber and PIR insulation, helping to negate any need for heavier engineering to protect the historic fabric (I think a max.of 9 resin fixings to the Victorian extension, will be sufficient to support the roof structure).

Additionally, the roof depth can be much reduced by using warm roof technology, and by using Lead capping and flashing to cover the upstand edges (including the Rooflight) then I hope that the resulting visual impression is of a fully lead lined roof. Please note there are no overlooking windows to this area, and at ground level lead is the only material seen.

 

A hidden gutter detail can also be implemented as part of the over-hang detail, behind the capped parapet. This can be drained via existing downpipe positions and removed from the eaves front, further simplifying the proposed elevation.

 

Please feel free to call me on 07979 542199 if required and convenient.

 

Many Thanks

David

On 13/01/2023 13:05 GMT David Guy <info@dg4design.co.uk> wrote:

 

 

Hi Heather,

Further to our telephone conversation; I can confirm an agreed extension of time till the 10th Feb.

 

I will look to sending you revised drawings as soon as possible, to enable all parties to examine details to support my wish to produce a warm roof construction as would be favoured by building control.

 

Many thanks for returning my call

Regards

David

 

 

On 12/01/2023 08:25 GMT Wynne, Heather <heather.wynne@ambervalley.gov.uk> wrote:

 

 

Dear David,

 

Further to your email, the Heritage Consultant has come back with the comments below.

 

Please can you look through the comments and let me know how you wish to proceed by the 16th January. The applications are due to expire on the 17th January. I am happy to agree to a suitable extension of time if you require further time to discuss with your clients and submit any amendments, however if an extension of time is not agreed by the 16th January, the applications will be determined as submitted.

 

Many thanks

Kind regards

Heather Wynne | Planning Assistant

Amber Valley Borough Council
Development Management | Town Hall, Ripley, Derbyshire, DE5 3BT
Email: 
heather.wynne@ambervalley.gov.uk | Telephone: 01773 841593
www.ambervalley.gov.uk

Making a difference for Amber Valley

 

From: Morris, Mel
Sent: 11 January 2023 15:59
To: Wynne, Heather <Heather.Wynne@ambervalley.gov.uk>
Subject: RE: AVA/2022/1021 and 0919 44 Long Row, Belper

 

Heather,

Thank you for the email and further details.  There are some aspects which are acceptable and some which are still not acceptable.  With regards to the replacement sash window, I suggest that this is conditioned as:

Notwithstanding the submitted details the first floor window shall be a copy of the existing single-glazed sash window in all respects.

A full size section of the glazing bar and meeting rail shall be submitted to and approved in writing by the Local Planning Authority.

 

I am of the view that the EPDM roof is still broadly unacceptable.  I have not objected to the proposed overhang.  The agent has explained that the roof is 400mm deep overall, but this must be designed to be slimmed down at the eaves, so that we do not have a bulky 400mm flat profile / fascia, which will be very unsightly.  This needs more refinement and given that there is a considerable overhang, I consider this is relatively easy to achieve with a bespoke detail.  In my view a parapet, in this context, is inappropriate and usually relates to a brick wall, which is not proposed in this instance.  Once we have agreed the material, then the roof joists can be designed to support the roof proposed.  At this stage, until we have agreement, I cannot make any informed comment about the joists. But we will still need to see a section to understand the physical impact on the historic fabric, and we should not simply accept the written description, as it is too vague at the moment.

 

I appreciate that there will be some instances where some rear extensions may have agreed different materials, but each of those will have been considered on its own merits, and these may be improvements. We have considered the rear elevations of the properties on Long Row which are experienced in conjunction with the current application and my considered opinion is based on the merits of this case and what is proposed to be replaced.

 

I am happy with the justification for the use of TLX.

I am happy with a condition for agreeing the detail of the powder coated aluminium doors.  This could be covered with full-size or 1:2 sectional drawings through the frame and opening door.

 

Kind regards

Mel

 

 

 

Mel Morris | Heritage Consultant

Development Management

Amber Valley Borough Council

Town Hall, Ripley, Derbyshire, DE5 3BT

Email: Mel.Morris@ambervalley.gov.uk

Tel: 07825 935295

 

From: Wynne, Heather <Heather.Wynne@ambervalley.gov.uk>
Sent: 11 January 2023 10:29
To: Morris, Mel <Mel.Morris@ambervalley.gov.uk>
Subject: FW: AVA/2022/1021 and 0919 44 Long Row, Belper

 

Hi Mel,

 

Please see below the agent’s response to your comments on the above application.

 

Please let me know if you require anything else.


Many thanks

 

Heather

 

Heather Wynne | Planning Assistant

Amber Valley Borough Council
Development Management | Town Hall, Ripley, Derbyshire, DE5 3BT
Email: 
heather.wynne@ambervalley.gov.uk | Telephone: 01773 841593
www.ambervalley.gov.uk

Making a difference for Amber Valley

 

From: David Guy <info@dg4design.co.uk>
Sent: 11 January 2023 10:08
To: Wynne, Heather <Heather.Wynne@ambervalley.gov.uk>
Subject: Re: AVA/2022/1021 and 0919 44 Long Row, Belper

 

Dear Heather,

I was contacted by Laura Anthony just before Christmas regarding Heritage comments ref: AVA/2022/1021&0919. A full response was requested for the 9th Jan, however this has been difficult due to the long Christmas shutdown. I attached some drawing revisions and have replied the best I can as below:

 

In observation of the thoughts raised by Mel Morris in her opening paragraph under Comments:

 

I would like to draw attention to the precedential nature of some of the neighboring homes and extensions to number 44 Long Row (Extracts are from the AVBC website - view a planning history)

 

No.50 Long Row: specifies - Ballasted "brown" roof on bituminous roofing membrane (Dwg 19-122-08-11). Whilst the "South Elevational drawing" (19-122-08-10) illustrates a full width extension obliterating any reading of the historical elevation. Ref: AVA/2019/0932 - Approved.

 

No.60 Long Row: specifies single ply membrane for the flat roof. ref: AVA/2014/1152 (later 2015/0028) Both Approved.

 

No.19 Long Row: specifies lead lined roof details (Approved AVA/2008/1223), however having interrogated the details - this is for a cold flat roof, and a detail very much not in line with current building regulation beliefs, whom are very much in favour of Warm flat roof designs due unless there are preceding design constraints.

 

No.58/59 Long Row: I Cannot find this application reference on the AVBC website? However, see attached photos, I believe it was built sometime around 2005-10?

This is a side & rear wrap-around, single storey extension & perfectly illustrates a similar design for 44, producing an elegant 400mm (plus) deep flat roof fascia in a prime and prominent position (being visible from both Long Row bridge cutting and William street). Though here it is adorned with some hints towards Edwardian Regency.

 

I would like to make a case for the design as proposed in my drawings: 

 

1). Building Regulations will require a nominal 400mm roof depth to satisfy a warm roof detail to attain the appropriate U-value, this may be slimmed down due to cross joists being a nominal 120mm deep or less (Engineer to confirm at appropriate stage)

 

2). The over-hang of 800mm is desirable both to:

a). To prevent overheating - this is a South facing elevation. and this will reduce direct sunlight exposure during the summer months.

b). An existing level threshold detail would benefit from a more substantial over-hang to prevent heavy rainfall from potentially flooding out the garden room. Splash back from continual rain usually preludes a 150mm step to prevent this sort of potential water ingress, which is not easily implemented in this case.

 

3). the roof is supported by 2.4m joists (nom. 450mm c/c's) between the outer wall of the Victorian extension and the (party) wall of number 43. As can be seen in attached photograph (1A), These can be attached to 2 timber carriers , mechanically fixed along these two walls and will provide easy fix solution for the joists at any position along the whole length.

 

4). It is proposed that a light weight timber roof is installed, nullifying the need for a substantial structure which has been assumed by Heritage. There is no cantilever design proposed, as the existing walls either side fully support a timber frame.

 

5). EPDM is used in other extensions of neighboring properties. A parapet detail is used in such cases, and perhaps this is suggested for use here? Please confirm.

 

6). I confirm Aluminium (door) frames with a PPC finish are intended, however could this not be stipulated as a condition instead of drawings being requested at this planning stage? I have enquired previously as to the appropriate level of drawings required to get permission in relation to cost balance.

 

6). As we maintain, Building Regs approval will be sought after a successful application: therefore engineering consultation and full details will be drawn prior to any construction phase.

 

7). it is agreed the gutter (joining) detail will either require a new cast iron connection detail OR we an keep the existing UPVC arrangement and drop the rainfall into the existing floor drain/grate. I'm sure this will be a cost decision, but cannot be determined at this stage.

 

In relation to Mel's other points (numbered to follow):

2. To renovate the outbuilding: we note there is no objection

 

3. Re-roofing: see attached E07 revA.  The details are from TLX and can be fitted as instructed without effecting roof heights. A 50mm airgap will exist behind the existing roofing felt and will be maintained as per revised drawing (TLX is designed to fit within this gap and maintains a 20mm unventilated gap as the product expands to 30mm).

 

4. Replace 1st Flr window: Please note we are not proposing a double glazed unit. I believe Mel has mis-interpreted the drawing (E05), perhaps believing the two separate sashes (shown in Jamb section) are one single sash with two panes of glass. I can assure this drawing shows only single glass panes. Additionally the 25mm glazing bars were presumed, but I draw attention to the fact that the drawing clearly states "All timber profiles to match existing. To be measured on site prior to re-production" if required we can supply measured details once application has been approved.

Regarding the inconsistencies: I have attached E05 revA to convey the putty detail to the external edges all round.

 

5. Garage: we note there is no objection

 

 

There's quite a lot covered by Mel, Please feel free to contact me on 07979 542199 if you want clarity on anything mentioned that I may have missed.

 

 

Kind Regards

David

 

 

 

 

 

On 23/12/2022 08:20 GMT Anthony, Laura <laura.anthony@ambervalley.gov.uk> wrote:

 

 

Hi David

 

I am sending on this email on behalf of Heather as she is now on leave.

 

The heritage comments have been received which are below. There are a number of issues which need to be addressed please could you send the required information and amendments by the 9th January if possible.

 

Please send the information directly the Heather.

 

Kind regards

 

 

 

 

From: Morris, Mel <Mel.Morris@ambervalley.gov.uk>
Sent: 22 December 2022 18:41
To: Wynne, Heather <Heather.Wynne@ambervalley.gov.uk>
Subject: AVA/2022/1021 and 0919 44 Long Row, Belper

 

Dear Heather

 

AVA/2022/1021 and AVA/2022/0919

44 Long Row, Belper DE56 1DS

Listed building consent

Replace conservatory with a timber flat roof (with rooflight) plus new bi-fold doors. Renovation works to existing slate roof. Replacement of rear window to 1st floor, re-introduction of outside toilet and door to outbuilding. Remove and replace existing garage building

 

Thank you for referring this application to me for heritage comments.

 

Significance

The property is one of a row of grade II listed Strutt Estate houses which have a very strong continuity of form and detail to both Long Row and the rear elevations to William Street.

 

Proposals

 

  1. 1. Replace the existing flat polycarbonate twin wall roof with a fully insulated warm EPDM flat roof (nominal fall of 1:60) complete with a roof light (nom 1x2m single storey and replace the existing conservatory with bi- fold doors to the south, with level threshold access.

 

Comments:

The rear elevations to the cottages along this side of Long Row have small extensions but the majority of these have been built in traditional form. The adjacent property (no. 43) has a monopitched roof with lead covering, adopting lead rolls. 

 

The current roof is lightweight and translucent.  Whilst the materials are not particularly sympathetic, it does enable us to see the rear elevation of the cottage.   It is reasonable to alter this to a solid roof, but in my view the proposal to use a modern EPDM is not in-keeping and would be harmful.  I would accept a Code 5 lead roof, with lead rolls.  This should be constructed with falls and details which comply with the Lead Sheet Association guidelines.  Lead flashings at Code 4 should be incorporated to replace the current ‘Flashband’.

 

It would be acceptable to introduce bi-fold doors in this one instance, as these are set deep in recess.  However, we need confirmation of the details, as there is one reference to aluminium.  Can we please see a section and confirmation that this is a powder-coated finish, and the colour, and confirmation that this is not a combined uPVC and aluminium frame.

 

The proposed roof section is deep and heavy with 800mm overhang and 400mm fascia.   The fascia is visually much too deep and needs some refinement.  The flashing is not shown.  It is going to need a substantial structure to support the roof.  The illustration suggests a cantilevered design but how is that going to be achieved?  Is this going to sit on the neighbouring wall or on posts?  No details have been provided to show how the new roof is going to be supported and to what extent the frame can support the roof.  As proposed, it is not clear to me how the roof and new rafters will be fixed, to what, and what the impact on the historic fabric is going to be.  Given the weight of the replacement roof, it may need an engineering input into the design.

 

What has been provided is not sufficiently detailed. Can we please see a detailed section showing the construction method, rafter section, proper section though the roof and revised details to show a lead roof finish, eaves treatment to slim down the profile, and the guttering details.  The existing downpipe is cast-iron, so I suspect it cannot simply be connected to the new rainwater pipe and will need further consideration or a completely new cast-iron gutter and downpipe, with connections.

 

  1. 2. To renovate the outbuilding by re-introducing the WC (and hand sink)

 

Comments:

I have no objections to the proposal.

 

  1. 3. Re-roofing

Existing battens will be removed, with an insulating weather lining (TLX) introduced and then the existing slates will be re-laid on new battens.

 

The specification for TLX mentions either fitting counter battens or alternatively draping the insulation between the rafters.  How will this be achieved and the 50mm air gap maintained?  There should be no change to the proof profile between the slate and the adjoining roof.   I would like confirmation that the air gap can be achieved whilst still using TLX and without counter-battening the roof.

 

  1. 4. Replace the first floor window with double glazed sealed units in sashes.

 

The proposal is unacceptable and would be harmful to the special interest of the listed building.  The existing sash windows are all single-glazed and are consistent throughout the Strutt properties along this side of Long Row.  There is no justification to replace them with double glazed windows.

 

The drawing submitted shows 25mm glazing bars, which are much fatter than the existing glazing bars, and also show timber profiles to the outside face of the glass, rather than putty, and an odd detail with weather strip where the sash sits almost flush with the outer bead on the frame.  The sections are odd and not a traditional detail, with 45mm meeting rails and 25mm glazing bars which do not match the existing historic sash windows.  The drawings are also inconsistent, with the section through the glazing bar, which is purported to be single glazed and putty finished, in contrast with the section through the frame which shows double glazing.  These details are, therefore, inconsistent.  The proposal is not acceptable and we should not approve it.  A like-with-like single glazed window is appropriate in this instance, to match all others in the row.

 

  1. 5. Garage – replace the existing garage with a concrete pre-fabricated garage, with cement particle roof panels, and a metal up-&-over door.

 

I have no objections to this proposal, which has neutral impact.

 

 

Kind regards

Mel

 

 

Mel Morris | Heritage Consultant

Development Management

Amber Valley Borough Council

Town Hall, Ripley, Derbyshire, DE5 3BT

Email: Mel.Morris@ambervalley.gov.uk

Tel: 07825 935295

 

This email is private. If you are not the intended recipient, please notify the sender by return, destroying the email without disclosing or relying upon it. We may by law have to disclose this email. We monitor both sent and received emails. The attachments are opened at your own risk.

This email is private. If you are not the intended recipient, please notify the sender by return, destroying the email without disclosing or relying upon it. We may by law have to disclose this email. We monitor both sent and received emails. The attachments are opened at your own risk.

This email is private. If you are not the intended recipient, please notify the sender by return, destroying the email without disclosing or relying upon it. We may by law have to disclose this email. We monitor both sent and received emails. The attachments are opened at your own risk.
P01revA Sections.pdf

</